Quality inspection

Measured to your drawing, signed before it ships.

Every order passes through our QC room before it’s packed, whether it was machined, cast, printed or finished. We measure each critical feature against your drawing, verify the material and the finish, and send you the measured values. Parts ship once you’ve seen the report.

  • A report with every orderMeasured values, not just a stamp.
  • ±0.005 mm CMMParts measured at 20 °C.
  • Traceable to the heatMill certs matched to your PO.
  • Remake guaranteeOut of spec means we remake it.
EC-4410Pump end cap, CNC turned and milled, clear anodized

Drawing received

Lot of 50Every part gets a visual check. 13 are picked at random and measured on every balloon.

Lot size

Parts measured
of 50
Results on the report
Time in QC
hours
Critical features only
0
Your plan
0

    Example part and lot, to show how sampling works. Your plan follows your drawing, your quantity and the features you mark as critical.

    By process

    What we check depends on how it was made

    A machined bore, a cast wall and a dyed finish fail in different ways, so each process gets its own checks on top of the dimensions on your drawing. Move the slider to see where a part stops passing.

    A part that crosses processes, say a casting that is machined and then anodized, gets every set of checks that applies to it.

    Our acceptance rule. A feature passes only inside its limit, with nothing rounded in its favor. Any reading within 10% of a limit is measured again, and position is always reported as a diameter against the datums on your drawing, not as loose X and Y values.

    What we check on machined parts 6 checks

    • Critical dimensions and GD&TBridge CMM, aligned to your datumsASME Y14.5, ISO 1101
    • Bores, holes and slotsBore gauges and pin gaugesISO 286 fits, e.g. H7
    • ThreadsGO / NO-GO plug and ring gaugesISO 965 6H/6g, UNC/UNF 2B/2A
    • Surface roughnessStylus roughness testerRa, Rz to ISO 21920
    • Everything else on the drawingCalipers, micrometers, height gaugeISO 2768-mK unless your drawing says otherwise
    • Edges, burrs and tool marksVisual check on every partCosmetic class on your drawing
    Checkpoints

    Five checkpoints between raw stock and your dock

    Every order passes all five, from a single prototype up. Select a checkpoint to see which part of the report it produces. The report mirrors the lot you inspected above.

    Outgoing inspection report

    EC-4410 Pump end cap

    Report QC-4410-B, drawing rev B, PO 2026-118

    ACCEPTED
    LOT 50
    Lot size50 pcs
    Measured13 pcs
    SamplingISO 2859-1, II
    QC room20.1 °C
    • IQC6061-T6, Ø95 bar. Heat 24-1187, XRF match, EN 10204 3.1 attached
    • FAIFirst article: 18 of 18 in tolerance. Approved by you on day 4
    • IPQCBore gauged every 10 parts. 5 entries, no tool offset needed
    Balloon and specLowHighResult
    • OQC50 pcs in 2 cartons. 8 packing photos, CoC signed
    Signed · Rhys, lead engineer Day 9 · 16:05
    Inspected in Purniss QC room

    Sample report for the example part. Yours lists every balloon on your drawing, with the measured values.

    Inspection lab

    The instruments behind every number

    What we measure your parts with, in our QC room and at the partner shops that make them. Every instrument carries a calibration label with its due date. Filter by process to see what checks yours.

    17 instruments across all four processes.

    • Dimensional7 instruments
      • Bridge CMMTouch-trigger and scanning probes
        GD&T, bores and datums, and full dimensional reports
        Range700 × 1000 × 600 mm
        Accuracy±0.005 mm
      • Vision measuring system2.5D optical, no contact
        Small features, thin walls and soft parts a caliper would squeeze
        Range400 × 300 × 200 mm
        Accuracy±0.003 mm
      • Blue-light 3D scannerFull-surface compare to CAD
        Warp, shrink and cast shape, shown as a color deviation map
        RangeParts 10–1000 mm
        Accuracy±0.02 mm
      • Height gauge and granite plateGrade 00 plate, 1000 × 750 mm
        Step heights and depths, and flatness with a dial indicator
        Range0–600 mm
        Accuracy±0.003 mm
      • Micrometers and bore gaugesOutside, inside and depth
        Diameters, bores and thickness, at the machine and in QC
        Range0–300 mm
        Accuracy±0.002 mm
      • Pin gauges and gauge blocks0.01 mm steps
        Hole sizes and slot widths, GO / NO-GO
        RangeØ0.5–20 mm
        Accuracy±0.001 mm
      • Thread gaugesPlug and ring, GO / NO-GO
        Every tapped hole and external thread, before and after coating
        RangeM1.6–M24, #2–1″
        Class6H/6g, 2B/2A
    • Surface and finish5 instruments
      • Surface roughness testerStylus profilometer
        Ra, Rz and Rq on machined, cast and printed faces
        RangeRa 0.05–10 µm
        Accuracy±5% of reading
      • Coating thickness gaugeEddy current and magnetic induction
        Anodize, powder coat, paint and plating, five points per face
        Range0–1500 µm
        Accuracy±(1 µm + 2%)
      • Spectrophotometerd/8°, D65 light, 10° observer
        Color against your chip, RAL or Pantone, reported as ΔE
        Range400–700 nm
        RepeatabilityΔE 0.05
      • Gloss meter20°, 60° and 85°
        Sheen on paint, powder coat and textured parts
        Range0–2000 GU
        Accuracy±1.5 GU
      • Cross-cut adhesion kit1, 2 and 3 mm blade spacing
        Paint and powder coat adhesion on a witness part
        RangeCoatings to 250 µm
        GradingClass 0–5, ISO 2409
    • Material and integrity5 instruments
      • Handheld XRF analyzerNon-destructive alloy check
        Aluminum, steel, stainless, brass and titanium grades, checked against the cert
        RangeElements Mg to U
        Accuracy±0.05 wt%, major
      • Hardness testersRockwell, Vickers, Shore A and D
        Heat-treated steel, aluminum tempers, rubber and polyurethane
        RangeHRC 20–70, Shore 10–90
        Accuracy±1 HRC, ±1 Shore
      • Digital X-rayPartner foundryDR panel, 225 kV
        Porosity, shrinkage and inclusions inside castings
        RangeAluminum walls to 40 mm
        Sensitivity2% IQI
      • Pressure-decay leak testerPartner shopDry air, every sealing part
        Housings, manifolds and covers that have to seal
        Range0.5–10 bar
        Resolution1 Pa
      • Dye penetrant kitVisible red, solvent removable
        Surface cracks and cold shuts on castings and welds
        RangeNon-porous metals
        SensitivityLevel 2, ISO 3452-2
    QC room
    20 ± 1 °CParts rest in the room for two hours before they go on the CMM.
    Calibration
    Every 12 monthsBy an accredited lab, traceable to national standards. Certificates on request.
    CMM check
    Every shiftA certified reference sphere is measured before the first part.
    Gauge control
    ID and due dateAn instrument past its due date is pulled from use until it’s recalibrated.

    In our QC room unless marked. X-ray and leak tests run at the partner shop that makes the part, and our QC team reviews the images and test logs before the parts ship.

    Caught before shipping

    What our checks stopped on real orders

    Four recent catches, one from each process we run. Open one to see what we found, how we contained it, and what changed so it doesn’t happen again.

    • What we found

      • Bore gauge read +0.017 mm at part 40, against a limit of +0.021
      • A steady climb of 2 µm per ten parts since the start of the shift

      What we did

      • Stopped the run and measured all 40 bores on the CMM: every one in tolerance
      • Reset the tool offset; the next 80 parts ran centered at +0.010

      What changed for good

      • An offset check every 15 parts, written into the routing for reorders
    • What we found

      • Pores up to Ø0.9 mm, 0.4 mm under the machined face
      • The drawing’s Zone A allows Ø0.5, and none that open

      What we did

      • Rejected the first-article castings before the batch was poured
      • The foundry added a vacuum vent and an overflow at the last corner to fill

      What changed for good

      • Every 50th casting X-rayed, and every cover leak-tested at 3 bar
    • What we found

      • Peak deviation of +0.42 mm at mid-length
      • All 60 arms from one build, all bowed the same way

      What we did

      • Reprinted the batch on its side at 30°, with a longer cool-down in the powder
      • Scanned every arm: highest deviation 0.17 mm

      What changed for good

      • Orientation and cool-down saved with the build file for reorders
    • What we found

      • 14 of 200 bezels between ΔE 1.9 and 2.1
      • All 14 came out of the second dye tank

      What we did

      • Stripped the 14 and anodized them again in the first tank
      • Measured all 200: highest ΔE 0.9

      What changed for good

      • One dye tank per order, and a color check on the first rack before the rest

    Shown without customer details. In each case the customer had the findings, the cause and the fix in writing before the parts shipped.

    Questions

    Before you order

    Still unsure? Send your drawing to [email protected] and an engineer will tell you exactly how it would be inspected.

    • Yes. Every order includes the standard inspection and an outgoing QC report with measured values. A full dimensional CMM report, an AS9102-format first article report, 100% inspection of a feature or a third-party inspection are quoted as separate lines, so you see the cost before you order.

    • The ones marked critical on your drawing, plus every thread, fit and finish callout. If nothing is marked, the engineer who reviews your drawing proposes which features to balloon, and you confirm before production. Everything else is held to the general tolerance on your drawing, or ISO 2768-mK if there isn’t one.

    • Every part on orders of up to 13. Above that we measure a random sample sized to ISO 2859-1, general inspection level II: 13 parts from a lot of 50, 32 from 200, 80 from 1,000. A lot is accepted only if every sampled part passes; if one fails, we measure every part in the lot. Features you mark as critical can be checked on every part.

    • It’s held, photographed and logged, and your engineer tells you the same working day, with the measurement. We sort the rest of the lot, remake or rework what failed at our cost, and send a root-cause report with the fix. If an out-of-spec part still reaches you, the remake guarantee covers it.

    • Yes. Send your inspection plan, sampling level, control plan or receiving checklist with the quote and we work to it. If your QA team has a report template, we fill that in instead of ours, with the same balloon numbers.

    • Yes. We hold the parts and host your inspector, or an agency such as SGS, TÜV or Bureau Veritas, in our QC room. We can also run the inspection on a live video call, with the CMM screen shared.

    • On request: EN 10204 3.1 mill certificates for metals, datasheets and lot records for polymers, and RoHS and REACH declarations. Each one is matched to your PO and drawing revision, and filed with the order for reorders.

    • Our QC system follows ISO 9001 practice: written procedures, calibrated instruments, traceable records and corrective actions. If your order needs a certified supplier, tell us at quote. We’ll confirm which partner shop holds the certificate you need, such as ISO 9001, IATF 16949 or AS9100, and send you a copy before you order.

    Remake guarantee

    Out of spec when it arrives? We remake it.

    If a part reaches you outside the limits on your approved drawing, send us your measurement or a photo within 30 days. We remake or refund it at our cost, and send you the root cause in writing.

    Upload CAD under strict NDA
    Talk to our team