Every order passes through our QC room before it’s packed, whether it was machined, cast, printed or finished. We measure each critical feature against your drawing, verify the material and the finish, and send you the measured values. Parts ship once you’ve seen the report.
A report with every orderMeasured values, not just a stamp.
±0.005 mm CMMParts measured at 20 °C.
Traceable to the heatMill certs matched to your PO.
Remake guaranteeOut of spec means we remake it.
EC-4410Pump end cap, CNC turned and milled, clear anodized
Drawing received
Lot of 50Every part gets a visual check. 13 are picked at random and measured on every balloon.
Visual check
Measured, passed
Held
Lot size
Parts measured
of 50
Results on the report
Time in QC
hours
Critical features only
0
Your plan
0
Example part and lot, to show how sampling works. Your plan follows your drawing, your quantity and the features you mark as critical.
By process
What we check depends on how it was made
A machined bore, a cast wall and a dyed finish fail in different ways, so each process gets its own checks on top of the dimensions on your drawing. Move the slider to see where a part stops passing.
A part that crosses processes, say a casting that is machined and then anodized, gets every set of checks that applies to it.
Our acceptance rule. A feature passes only inside its limit, with nothing rounded in its favor. Any reading within 10% of a limit is measured again, and position is always reported as a diameter against the datums on your drawing, not as loose X and Y values.
What we check on machined parts 6 checks
Critical dimensions and GD&TBridge CMM, aligned to your datumsASME Y14.5, ISO 1101
Bores, holes and slotsBore gauges and pin gaugesISO 286 fits, e.g. H7
ThreadsGO / NO-GO plug and ring gaugesISO 965 6H/6g, UNC/UNF 2B/2A
Surface roughnessStylus roughness testerRa, Rz to ISO 21920
Everything else on the drawingCalipers, micrometers, height gaugeISO 2768-mK unless your drawing says otherwise
Edges, burrs and tool marksVisual check on every partCosmetic class on your drawing
Our acceptance rule. Faces that seal or get machined are Zone A: no pore over 0.5 mm, and none that opens when the face is cut. Everything else is Zone B, graded against the ASTM E505 reference radiographs. Zones and grades on your drawing replace ours.
What we check on castings 6 checks
Porosity and shrinkageDigital X-ray at the foundry, images reviewed by our QC teamASTM E505 (die cast), E155 (sand, investment)
Cast shape and warpBlue-light 3D scan against your CADISO 8062-3 tolerance grades
Machined featuresCMM and gauges, as for CNC partsYour drawing
Pressure tightnessPressure-decay leak test on parts that sealTest pressure and leak rate from your spec
Surface cracks and cold shutsDye penetrantISO 3452-1
AlloyXRF on the ingot and the first castings, plus the certEN 1706, ASTM B85 or your spec
Our acceptance rule. Printed and cast polymer parts keep moving after they leave the printer or the mold, so we scan them after 24 hours at room temperature, never straight off the machine. Dimensions without a tolerance are held to the general tolerance for that process in our capability sheet.
What we check on printed and molded parts 6 checks
Shape against CAD: warp, sink, shrinkBlue-light 3D scan, color deviation mapYour drawing or our capability sheet
Small features and thin wallsVision system, so soft parts aren’t squeezed by a caliperYour drawing
HardnessShore A and Shore D durometersISO 868, ASTM D2240
Fit and functionSnap fits, inserts and mating parts tried by handYour mating part or our gauge
Cosmetics and colorVisual under D65 light, color against your chipYour cosmetic spec
MaterialResin or powder lot logged for every buildMaker’s datasheet and certs on request
Our acceptance rule. Every reading has to sit inside your range, not just the average, because edges and corners build up faster than flat faces. We read five points per face, and add color and gloss readings for any finish with a color or a sheen on the drawing.
What we check on finished parts 6 checks
Coating thicknessEddy current on aluminum, magnetic induction on steelISO 2360, ISO 2178
ColorSpectrophotometer against your chip, RAL or Pantone, under D65ΔE limit from your drawing
GlossGloss meter at 20°, 60° or 85°ISO 2813
AdhesionCross-cut tape test on a witness partISO 2409, ASTM D3359
Masked bores and threadsPin and thread gauges after coatingSame limits as before coating
CosmeticsVisual under daylight-balanced light, Class A faces firstYour cosmetic class
Checkpoints
Five checkpoints between raw stock and your dock
Every order passes all five, from a single prototype up. Select a checkpoint to see which part of the report it produces. The report mirrors the lot you inspected above.
Outgoing inspection report
EC-4410 Pump end cap
Report QC-4410-B, drawing rev B, PO 2026-118
ACCEPTED LOT 50
Lot size50 pcs
Measured13 pcs
SamplingISO 2859-1, II
QC room20.1 °C
IQC6061-T6, Ø95 bar. Heat 24-1187, XRF match, EN 10204 3.1 attached
FAIFirst article: 18 of 18 in tolerance. Approved by you on day 4
IPQCBore gauged every 10 parts. 5 entries, no tool offset needed
Balloon and spec
Low
High
Result
OQC50 pcs in 2 cartons. 8 packing photos, CoC signed
Signed · Rhys, lead engineer
Day 9 · 16:05
Inspected in
Purniss QC room
Sample report for the example part. Yours lists every balloon on your drawing, with the measured values.
Inspection lab
The instruments behind every number
What we measure your parts with, in our QC room and at the partner shops that make them. Every instrument carries a calibration label with its due date. Filter by process to see what checks yours.
17 instruments across all four processes.
InstrumentWhat it checksRangeAccuracyUsed on
Dimensional7 instruments
Bridge CMMTouch-trigger and scanning probes
GD&T, bores and datums, and full dimensional reports
Range700 × 1000 × 600 mm
Accuracy±0.005 mm
Vision measuring system2.5D optical, no contact
Small features, thin walls and soft parts a caliper would squeeze
Range400 × 300 × 200 mm
Accuracy±0.003 mm
Blue-light 3D scannerFull-surface compare to CAD
Warp, shrink and cast shape, shown as a color deviation map
RangeParts 10–1000 mm
Accuracy±0.02 mm
Height gauge and granite plateGrade 00 plate, 1000 × 750 mm
Step heights and depths, and flatness with a dial indicator
Range0–600 mm
Accuracy±0.003 mm
Micrometers and bore gaugesOutside, inside and depth
Diameters, bores and thickness, at the machine and in QC
Range0–300 mm
Accuracy±0.002 mm
Pin gauges and gauge blocks0.01 mm steps
Hole sizes and slot widths, GO / NO-GO
RangeØ0.5–20 mm
Accuracy±0.001 mm
Thread gaugesPlug and ring, GO / NO-GO
Every tapped hole and external thread, before and after coating
RangeM1.6–M24, #2–1″
Class6H/6g, 2B/2A
Surface and finish5 instruments
Surface roughness testerStylus profilometer
Ra, Rz and Rq on machined, cast and printed faces
RangeRa 0.05–10 µm
Accuracy±5% of reading
Coating thickness gaugeEddy current and magnetic induction
Anodize, powder coat, paint and plating, five points per face
Range0–1500 µm
Accuracy±(1 µm + 2%)
Spectrophotometerd/8°, D65 light, 10° observer
Color against your chip, RAL or Pantone, reported as ΔE
Range400–700 nm
RepeatabilityΔE 0.05
Gloss meter20°, 60° and 85°
Sheen on paint, powder coat and textured parts
Range0–2000 GU
Accuracy±1.5 GU
Cross-cut adhesion kit1, 2 and 3 mm blade spacing
Paint and powder coat adhesion on a witness part
RangeCoatings to 250 µm
GradingClass 0–5, ISO 2409
Material and integrity5 instruments
Handheld XRF analyzerNon-destructive alloy check
Aluminum, steel, stainless, brass and titanium grades, checked against the cert
RangeElements Mg to U
Accuracy±0.05 wt%, major
Hardness testersRockwell, Vickers, Shore A and D
Heat-treated steel, aluminum tempers, rubber and polyurethane
RangeHRC 20–70, Shore 10–90
Accuracy±1 HRC, ±1 Shore
Digital X-rayPartner foundryDR panel, 225 kV
Porosity, shrinkage and inclusions inside castings
RangeAluminum walls to 40 mm
Sensitivity2% IQI
Pressure-decay leak testerPartner shopDry air, every sealing part
Housings, manifolds and covers that have to seal
Range0.5–10 bar
Resolution1 Pa
Dye penetrant kitVisible red, solvent removable
Surface cracks and cold shuts on castings and welds
RangeNon-porous metals
SensitivityLevel 2, ISO 3452-2
QC room
20 ± 1 °CParts rest in the room for two hours before they go on the CMM.
Calibration
Every 12 monthsBy an accredited lab, traceable to national standards. Certificates on request.
CMM check
Every shiftA certified reference sphere is measured before the first part.
Gauge control
ID and due dateAn instrument past its due date is pulled from use until it’s recalibrated.
In our QC room unless marked. X-ray and leak tests run at the partner shop that makes the part, and our QC team reviews the images and test logs before the parts ship.
Caught before shipping
What our checks stopped on real orders
Four recent catches, one from each process we run. Open one to see what we found, how we contained it, and what changed so it doesn’t happen again.
PartWhat we foundCaught atDelay to you
What we found
Bore gauge read +0.017 mm at part 40, against a limit of +0.021
A steady climb of 2 µm per ten parts since the start of the shift
What we did
Stopped the run and measured all 40 bores on the CMM: every one in tolerance
Reset the tool offset; the next 80 parts ran centered at +0.010
What changed for good
An offset check every 15 parts, written into the routing for reorders
What we found
Pores up to Ø0.9 mm, 0.4 mm under the machined face
The drawing’s Zone A allows Ø0.5, and none that open
What we did
Rejected the first-article castings before the batch was poured
The foundry added a vacuum vent and an overflow at the last corner to fill
What changed for good
Every 50th casting X-rayed, and every cover leak-tested at 3 bar
What we found
Peak deviation of +0.42 mm at mid-length
All 60 arms from one build, all bowed the same way
What we did
Reprinted the batch on its side at 30°, with a longer cool-down in the powder
Scanned every arm: highest deviation 0.17 mm
What changed for good
Orientation and cool-down saved with the build file for reorders
What we found
14 of 200 bezels between ΔE 1.9 and 2.1
All 14 came out of the second dye tank
What we did
Stripped the 14 and anodized them again in the first tank
Measured all 200: highest ΔE 0.9
What changed for good
One dye tank per order, and a color check on the first rack before the rest
Shown without customer details. In each case the customer had the findings, the cause and the fix in writing before the parts shipped.
Questions
Before you order
Still unsure? Send your drawing to [email protected] and an engineer will tell you exactly how it would be inspected.
Yes. Every order includes the standard inspection and an outgoing QC report with measured values. A full dimensional CMM report, an AS9102-format first article report, 100% inspection of a feature or a third-party inspection are quoted as separate lines, so you see the cost before you order.
The ones marked critical on your drawing, plus every thread, fit and finish callout. If nothing is marked, the engineer who reviews your drawing proposes which features to balloon, and you confirm before production. Everything else is held to the general tolerance on your drawing, or ISO 2768-mK if there isn’t one.
Every part on orders of up to 13. Above that we measure a random sample sized to ISO 2859-1, general inspection level II: 13 parts from a lot of 50, 32 from 200, 80 from 1,000. A lot is accepted only if every sampled part passes; if one fails, we measure every part in the lot. Features you mark as critical can be checked on every part.
It’s held, photographed and logged, and your engineer tells you the same working day, with the measurement. We sort the rest of the lot, remake or rework what failed at our cost, and send a root-cause report with the fix. If an out-of-spec part still reaches you, the remake guarantee covers it.
Yes. Send your inspection plan, sampling level, control plan or receiving checklist with the quote and we work to it. If your QA team has a report template, we fill that in instead of ours, with the same balloon numbers.
Yes. We hold the parts and host your inspector, or an agency such as SGS, TÜV or Bureau Veritas, in our QC room. We can also run the inspection on a live video call, with the CMM screen shared.
On request: EN 10204 3.1 mill certificates for metals, datasheets and lot records for polymers, and RoHS and REACH declarations. Each one is matched to your PO and drawing revision, and filed with the order for reorders.
Our QC system follows ISO 9001 practice: written procedures, calibrated instruments, traceable records and corrective actions. If your order needs a certified supplier, tell us at quote. We’ll confirm which partner shop holds the certificate you need, such as ISO 9001, IATF 16949 or AS9100, and send you a copy before you order.
Remake guarantee
Out of spec when it arrives? We remake it.
If a part reaches you outside the limits on your approved drawing, send us your measurement or a photo within 30 days. We remake or refund it at our cost, and send you the root cause in writing.